Views: 0 Author: Site Editor Publish Time: 2024-05-13 Origin: Site
1、 Add 10-15% oxalic acid solution into the storage tank so that the liquid level of the oxalic acid solution just covers the ceramic plate.
2、Place the ceramic plate to be cleaned vertically into the oxalic acid solution, with the ceramic plate nozzle facing upward and keeping it above the liquid level.
3、Soak the ceramic plate in the oxalic acid solution for 3-7 days. The specific time is adjusted according to the degree of blockage of the ceramic plate.
4、Backflush the soaked ceramic plates with compressed air at a backflush pressure of 0.2-0.4MPa.
5、Install the cleaned ceramic plates into the machine for use or store them for later use.
Note : Always keep the faucet of the ceramic plate above the liquid level during soaking to prevent magazines from entering the interior of the ceramic plate from the faucet.
Nuclear Industry Yantai Toncin Group Co., Ltd. Located in Shandong province, China, which integrated enterprises of filter industry, wrapping machine, advanced manufacturing industry and new materials industry, formed the industrial pattern of common development of filtration separation machinery, wrapping machine, new material industry and high-end equipment industry.
Nuclear Industry Yantai Toncin Group Co.,Ltd.specializes in the design, production and sales of solid-liquid separation equipment. The main products are: belt filter, ceramic filter, vertical filter press, thickener and accessories: rubber filter belt, rubber diaphragm, ceramic filter plate, filter cloth, control system, etc.